665 W IBC solar panel with 144 cells. Voc 54.52 V · Isc 15.35 A · TcVoc -0.2%/°C.
Select the panel you want to replace
53 panels found · 3647 panels excluded
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.52 V | 0.0% |
| Vmpp | 45.17 V | 45.17 V | 0.0% |
| Isc | 15.35 A | 15.38 A | 0.2% |
| Impp | 14.72 A | 14.72 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.52 V | 0.0% |
| Vmpp | 45.17 V | 45.17 V | 0.0% |
| Isc | 15.35 A | 15.35 A | 0.0% |
| Impp | 14.72 A | 14.72 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.52 V | 0.0% |
| Vmpp | 45.17 V | 45.17 V | 0.0% |
| Isc | 15.35 A | 15.38 A | 0.2% |
| Impp | 14.72 A | 14.72 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
665 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.52 V | 0.0% |
| Vmpp | 45.17 V | 45.17 V | 0.0% |
| Isc | 15.35 A | 15.38 A | 0.2% |
| Impp | 14.72 A | 14.72 A | 0.0% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.61 V | 0.2% |
| Vmpp | 45.17 V | 45.12 V | 0.1% |
| Isc | 15.35 A | 15.28 A | 0.5% |
| Impp | 14.72 A | 14.63 A | 0.6% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.42 V | 0.2% |
| Vmpp | 45.17 V | 45.07 V | 0.2% |
| Isc | 15.35 A | 15.3 A | 0.3% |
| Impp | 14.72 A | 14.65 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.42 V | 0.2% |
| Vmpp | 45.17 V | 45.07 V | 0.2% |
| Isc | 15.35 A | 15.3 A | 0.3% |
| Impp | 14.72 A | 14.65 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.42 V | 0.2% |
| Vmpp | 45.17 V | 45.07 V | 0.2% |
| Isc | 15.35 A | 15.3 A | 0.3% |
| Impp | 14.72 A | 14.65 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.42 V | 0.2% |
| Vmpp | 45.17 V | 45.07 V | 0.2% |
| Isc | 15.35 A | 15.3 A | 0.3% |
| Impp | 14.72 A | 14.65 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.42 V | 0.2% |
| Vmpp | 45.17 V | 45.07 V | 0.2% |
| Isc | 15.35 A | 15.3 A | 0.3% |
| Impp | 14.72 A | 14.65 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
660 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.42 V | 0.2% |
| Vmpp | 45.17 V | 45.07 V | 0.2% |
| Isc | 15.35 A | 15.3 A | 0.3% |
| Impp | 14.72 A | 14.65 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
670 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 54.52 V | 54.62 V | 0.2% |
| Vmpp | 45.17 V | 45.27 V | 0.2% |
| Isc | 15.35 A | 15.46 A | 0.7% |
| Impp | 14.72 A | 14.8 A | 0.5% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
54.52 V
Vmpp
45.17 V
Isc
15.35 A
Impp
14.72 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
665 W
Cells
144
Bifaciality
70%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
33.5 kg
The RECOM RCM-665-7DBRCF is a 665 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 640 W | 54.02 V | 14.98 A | |
| 645 W | 54.12 V | 15.06 A | |
| 650 W | 54.22 V | 15.14 A | |
| 655 W | 54.32 V | 15.22 A | |
| 660 W | 54.42 V | 15.3 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 54.52 V (within ±5%), and temperature coefficient TcVoc close to -0.2%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original RECOM RCM-665-7DBRCF.