675 W PERC solar panel with 414 cells. Voc 47.2 V · Isc 18.36 A · TcVoc -0.27%/°C.
Select the panel you want to replace
Panel not in the catalogue?
4 of the 4,444 panels in the catalogue can replace RECOM RCM-675-SDMT2. Before you buy, check your pick in the string calculator with your inverter.
CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.
Near-identical electrics — a drop-in swap for the same string.
Match 95 % · 1 model
Small differences within tolerance — safe once verified in the calculator with your inverter.
Match 84–90 % · 2 models
Noticeable differences — the string voltage and current need a careful check.
Match 79 % · 1 model
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
47.2 V
Vmpp
39.2 V
Isc
18.36 A
Impp
17.26 A
TcVoc
-0.27 %/°C
TcPmax
-0.34 %/°C
Pmax
675 W
Cells
414
Bifaciality
70%
Length
2384 mm
Width
1303 mm
Thickness
35 mm
Weight
38.5 kg
The RECOM RCM-675-SDMT2 is a 675 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| RCM-645-SDMT2 | 645 W | 46.6 V | 17.74 A |
| RCM-650-SDMT2 | 650 W | 46.7 V | 17.84 A |
| RCM-655-SDMT2 | 655 W | 46.8 V | 17.97 A |
| RCM-660-SDMT2 | 660 W | 46.9 V | 18.06 A |
| RCM-665-SDMT2 | 665 W | 47 V | 18.16 A |
| RCM-670-SDMT2 | 670 W | 47.1 V | 18.26 A |
The most critical specs to match are: cell count (must be exactly 414), Voc close to 47.2 V (within ±5%), and temperature coefficient TcVoc close to -0.27%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original RECOM RCM-675-SDMT2.