All replacements

Find replacement for Risen RSM120-8-595M

595 W PERC solar panel with 120 cells. Voc 41.4 V · Isc 18.26 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

18 panels found · 3692 panels excluded

Yingli Solar YL600D-60f 1/2

600 W

PERC
94Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.5 V0.2%
Vmpp34.5 V34.5 V0.0%
Isc18.26 A18.51 A1.4%
Impp17.25 A17.39 A0.8%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Yingli Solar YL595D-60f 1/2

595 W

PERC
92Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.3 V0.2%
Vmpp34.5 V34.3 V0.6%
Isc18.26 A18.45 A1.0%
Impp17.25 A17.35 A0.6%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Risen RSM120-8-590M

590 W

PERC
91Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.2 V0.5%
Vmpp34.5 V34.32 V0.5%
Isc18.26 A18.21 A0.3%
Impp17.25 A17.2 A0.3%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Risen RSM120-8-600M

600 W

PERC
91Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.6 V0.5%
Vmpp34.5 V34.7 V0.6%
Isc18.26 A18.32 A0.3%
Impp17.25 A17.3 A0.3%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Canadian Solar CS7L-600MS

600 W

PERC
85Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.3 V0.2%
Vmpp34.5 V34.9 V1.2%
Isc18.26 A18.47 A1.2%
Impp17.25 A17.2 A0.3%
TcVoc-0.25 %/°C-0.26 %/°C±0.010 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Yingli Solar YL590D-60f 1/2

590 W

PERC
85Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.1 V0.7%
Vmpp34.5 V34.1 V1.2%
Isc18.26 A18.32 A0.3%
Impp17.25 A17.31 A0.3%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Yingli Solar YL605D-60f 1/2

605 W

PERC
85Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.7 V0.7%
Vmpp34.5 V34.7 V0.6%
Isc18.26 A18.56 A1.6%
Impp17.25 A17.44 A1.1%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Risen RSM120-8-605M

605 W

PERC
82Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.8 V1.0%
Vmpp34.5 V34.88 V1.1%
Isc18.26 A18.37 A0.6%
Impp17.25 A17.35 A0.6%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Canadian Solar CS7L-605MS

605 W

PERC
82Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.5 V0.2%
Vmpp34.5 V35.1 V1.7%
Isc18.26 A18.52 A1.4%
Impp17.25 A17.25 A0.0%
TcVoc-0.25 %/°C-0.26 %/°C±0.010 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Canadian Solar CS7L-595MS

595 W

PERC
81Good match
ParameterOriginalReplacementDeviation
Voc41.4 V41.1 V0.7%
Vmpp34.5 V34.7 V0.6%
Isc18.26 A18.42 A0.9%
Impp17.25 A17.15 A0.6%
TcVoc-0.25 %/°C-0.26 %/°C±0.010 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Canadian Solar CS7L-590MS

590 W

PERC
78Acceptable
ParameterOriginalReplacementDeviation
Voc41.4 V40.9 V1.2%
Vmpp34.5 V34.5 V0.0%
Isc18.26 A18.37 A0.6%
Impp17.25 A17.11 A0.8%
TcVoc-0.25 %/°C-0.26 %/°C±0.010 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C
Yingli Solar YL585D-60f 1/2

585 W

PERC
77Acceptable
ParameterOriginalReplacementDeviation
Voc41.4 V40.9 V1.2%
Vmpp34.5 V33.9 V1.7%
Isc18.26 A18.28 A0.1%
Impp17.25 A17.26 A0.1%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.34 %/°C-0.34 %/°C±0.000 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

41.4 V

Vmpp

34.5 V

Isc

18.26 A

Impp

17.25 A

TcVoc

-0.25 %/°C

TcPmax

-0.34 %/°C

Pmax

595 W

Cells

120

Length

2172 mm

Width

1303 mm

Thickness

35 mm

Weight

30 kg

The Risen RSM120-8-595M is a 595 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
RSM120-8-590M590 W41.2 V18.21 A
RSM120-8-600M600 W41.6 V18.32 A
RSM120-8-605M605 W41.8 V18.37 A
RSM120-8-610M610 W42 V18.42 A
RSM120-8-615M615 W42.2 V18.47 A

Frequently Asked Questions

What specs must match when replacing the Risen RSM120-8-595M?

The most critical specs to match are: cell count (must be exactly 120), Voc close to 41.4 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Risen RSM120-8-595M?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Risen RSM120-8-595M.