Find replacement for S-Energy SL65-60MAJ-440Z

440 W PERC solar panel with 120 cells. Voc 41 V · Isc 13.64 A · TcVoc -0.29%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

27 panels found · 4312 panels excluded

S-Energy SL65-60MBJ-440Z

440 W

PERC
100Exact match
ParameterOriginalReplacementDeviation
Voc41 V41 V0.0%
Vmpp34.1 V34.1 V0.0%
Isc13.64 A13.64 A0.0%
Impp12.91 A12.91 A0.0%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MAJ-445Z

445 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41 V41.2 V0.5%
Vmpp34.1 V34.3 V0.6%
Isc13.64 A13.71 A0.5%
Impp12.91 A12.98 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MBJ-445Z

445 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41 V41.2 V0.5%
Vmpp34.1 V34.3 V0.6%
Isc13.64 A13.71 A0.5%
Impp12.91 A12.98 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MAJ-435Z

435 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41 V40.8 V0.5%
Vmpp34.1 V33.9 V0.6%
Isc13.64 A13.57 A0.5%
Impp12.91 A12.84 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MAJ-450Z

450 W

PERC
80Good match
ParameterOriginalReplacementDeviation
Voc41 V41.4 V1.0%
Vmpp34.1 V34.5 V1.2%
Isc13.64 A13.78 A1.0%
Impp12.91 A13.05 A1.1%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MBJ-450Z

450 W

PERC
80Good match
ParameterOriginalReplacementDeviation
Voc41 V41.4 V1.0%
Vmpp34.1 V34.5 V1.2%
Isc13.64 A13.78 A1.0%
Impp12.91 A13.05 A1.1%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
Phono Solar PS450M6-20/UH

450 W

PERC
72Acceptable
ParameterOriginalReplacementDeviation
Voc41 V40.87 V0.3%
Vmpp34.1 V34.23 V0.4%
Isc13.64 A13.72 A0.6%
Impp12.91 A13.15 A1.9%
TcVoc-0.29 %/°C-0.26 %/°C±0.030 %/°C
TcPmax-0.35 %/°C-0.33 %/°C±0.020 %/°C
Phono Solar PS455M6-20/UH

455 W

PERC
72Acceptable
ParameterOriginalReplacementDeviation
Voc41 V41.02 V0.0%
Vmpp34.1 V34.37 V0.8%
Isc13.64 A13.82 A1.3%
Impp12.91 A13.24 A2.6%
TcVoc-0.29 %/°C-0.26 %/°C±0.030 %/°C
TcPmax-0.35 %/°C-0.33 %/°C±0.020 %/°C
S-Energy SL65-60MAJ-455Z

455 W

PERC
70Acceptable
ParameterOriginalReplacementDeviation
Voc41 V41.6 V1.5%
Vmpp34.1 V34.7 V1.8%
Isc13.64 A13.85 A1.5%
Impp12.91 A13.12 A1.6%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MBJ-455Z

455 W

PERC
70Acceptable
ParameterOriginalReplacementDeviation
Voc41 V41.6 V1.5%
Vmpp34.1 V34.7 V1.8%
Isc13.64 A13.85 A1.5%
Impp12.91 A13.12 A1.6%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
Phono Solar PS445M6-20/UH

445 W

PERC
70Acceptable
ParameterOriginalReplacementDeviation
Voc41 V40.71 V0.7%
Vmpp34.1 V34.08 V0.1%
Isc13.64 A13.62 A0.1%
Impp12.91 A13.06 A1.2%
TcVoc-0.29 %/°C-0.26 %/°C±0.030 %/°C
TcPmax-0.35 %/°C-0.33 %/°C±0.020 %/°C
Perlight Solar PLM-450H8M-120

450 W

PERC
70Acceptable
ParameterOriginalReplacementDeviation
Voc41 V41.21 V0.5%
Vmpp34.1 V33.83 V0.8%
Isc13.64 A13.84 A1.5%
Impp12.91 A13.3 A3.0%
TcVoc-0.29 %/°C-0.27 %/°C±0.020 %/°C
TcPmax-0.35 %/°C-0.33 %/°C±0.020 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

41 V

Vmpp

34.1 V

Isc

13.64 A

Impp

12.91 A

TcVoc

-0.29 %/°C

TcPmax

-0.35 %/°C

Pmax

440 W

Cells

120

Length

1914 mm

Width

1134 mm

Thickness

30 mm

Weight

24 kg

The S-Energy SL65-60MAJ-440Z is a 440 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
SL65-60MAJ-435Z435 W40.8 V13.57 A
SL65-60MAJ-445Z445 W41.2 V13.71 A
SL65-60MAJ-450Z450 W41.4 V13.78 A
SL65-60MAJ-455Z455 W41.6 V13.85 A
SL65-60MAJ-460Z460 W41.8 V13.92 A

Frequently Asked Questions

What specs must match when replacing the S-Energy SL65-60MAJ-440Z?

The most critical specs to match are: cell count (must be exactly 120), Voc close to 41 V (within ±5%), and temperature coefficient TcVoc close to -0.29%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the S-Energy SL65-60MAJ-440Z?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original S-Energy SL65-60MAJ-440Z.