Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for S-Energy SL65-60MAJ-455Z

455 W PERC solar panel with 120 cells. Voc 41.6 V · Isc 13.85 A · TcVoc -0.29%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

34 panels found · 4305 panels excluded

S-Energy SL65-60MBJ-455Z

455 W

PERC
100Exact match
ParameterOriginalReplacementDeviation
Voc41.6 V41.6 V0.0%
Vmpp34.7 V34.7 V0.0%
Isc13.85 A13.85 A0.0%
Impp13.12 A13.12 A0.0%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
Luxor Solar LX-450M/182-120+ BW HC

450 W

PERC
91Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.55 V0.1%
Vmpp34.7 V34.65 V0.1%
Isc13.85 A13.79 A0.4%
Impp13.12 A12.99 A1.0%
TcVoc-0.29 %/°C-0.285 %/°C±0.005 %/°C
TcPmax-0.35 %/°C-0.36 %/°C±0.010 %/°C
S-Energy SL65-60MAJ-450Z

450 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.4 V0.5%
Vmpp34.7 V34.5 V0.6%
Isc13.85 A13.78 A0.5%
Impp13.12 A13.05 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MAJ-460Z

460 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.8 V0.5%
Vmpp34.7 V34.9 V0.6%
Isc13.85 A13.92 A0.5%
Impp13.12 A13.19 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MBJ-450Z

450 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.4 V0.5%
Vmpp34.7 V34.5 V0.6%
Isc13.85 A13.78 A0.5%
Impp13.12 A13.05 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MBJ-460Z

460 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.8 V0.5%
Vmpp34.7 V34.9 V0.6%
Isc13.85 A13.92 A0.5%
Impp13.12 A13.19 A0.5%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
Luxor Solar LX-455M/182-120+ BW HC

455 W

PERC
90Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.7 V0.2%
Vmpp34.7 V34.78 V0.2%
Isc13.85 A13.9 A0.4%
Impp13.12 A13.09 A0.2%
TcVoc-0.29 %/°C-0.285 %/°C±0.005 %/°C
TcPmax-0.35 %/°C-0.36 %/°C±0.010 %/°C
Luxor Solar LX-460M/182-120+ BW HC

460 W

PERC
83Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.85 V0.6%
Vmpp34.7 V34.9 V0.6%
Isc13.85 A14 A1.1%
Impp13.12 A13.19 A0.5%
TcVoc-0.29 %/°C-0.285 %/°C±0.005 %/°C
TcPmax-0.35 %/°C-0.36 %/°C±0.010 %/°C
S-Energy SL65-60MAJ-445Z

445 W

PERC
80Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.2 V1.0%
Vmpp34.7 V34.3 V1.2%
Isc13.85 A13.71 A1.0%
Impp13.12 A12.98 A1.1%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
S-Energy SL65-60MBJ-445Z

445 W

PERC
80Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.2 V1.0%
Vmpp34.7 V34.3 V1.2%
Isc13.85 A13.71 A1.0%
Impp13.12 A12.98 A1.1%
TcVoc-0.29 %/°C-0.29 %/°C±0.000 %/°C
TcPmax-0.35 %/°C-0.35 %/°C±0.000 %/°C
Sunpro Power SP450-120M10

450 W

PERC
80Good match
ParameterOriginalReplacementDeviation
Voc41.6 V41.5 V0.2%
Vmpp34.7 V34.81 V0.3%
Isc13.85 A13.7 A1.1%
Impp13.12 A12.93 A1.4%
TcVoc-0.29 %/°C-0.27 %/°C±0.020 %/°C
TcPmax-0.35 %/°C-0.34 %/°C±0.010 %/°C
Sunpro Power SP455-120M10

455 W

PERC
78Acceptable
ParameterOriginalReplacementDeviation
Voc41.6 V41.7 V0.2%
Vmpp34.7 V35.06 V1.0%
Isc13.85 A13.75 A0.7%
Impp13.12 A12.98 A1.1%
TcVoc-0.29 %/°C-0.27 %/°C±0.020 %/°C
TcPmax-0.35 %/°C-0.34 %/°C±0.010 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

41.6 V

Vmpp

34.7 V

Isc

13.85 A

Impp

13.12 A

TcVoc

-0.29 %/°C

TcPmax

-0.35 %/°C

Pmax

455 W

Cells

120

Length

1914 mm

Width

1134 mm

Thickness

30 mm

Weight

24 kg

The S-Energy SL65-60MAJ-455Z is a 455 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
SL65-60MAJ-435Z435 W40.8 V13.57 A
SL65-60MAJ-440Z440 W41 V13.64 A
SL65-60MAJ-445Z445 W41.2 V13.71 A
SL65-60MAJ-450Z450 W41.4 V13.78 A
SL65-60MAJ-460Z460 W41.8 V13.92 A

Frequently Asked Questions

What specs must match when replacing the S-Energy SL65-60MAJ-455Z?

The most critical specs to match are: cell count (must be exactly 120), Voc close to 41.6 V (within ±5%), and temperature coefficient TcVoc close to -0.29%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the S-Energy SL65-60MAJ-455Z?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original S-Energy SL65-60MAJ-455Z.