425 W PERC solar panel with 108 cells. Voc 37.96 V · Isc 14.08 A · TcVoc -0.27%/°C.
Select the panel you want to replace
86 panels found · 3344 panels excluded
425 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.9 V | 0.2% |
| Vmpp | 31.9 V | 31.94 V | 0.1% |
| Isc | 14.08 A | 14.08 A | 0.0% |
| Impp | 13.33 A | 13.31 A | 0.2% |
| TcVoc | -0.27 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.75 V | 0.6% |
| Vmpp | 31.9 V | 31.73 V | 0.5% |
| Isc | 14.08 A | 14.01 A | 0.5% |
| Impp | 13.33 A | 13.24 A | 0.7% |
| TcVoc | -0.27 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.75 V | 0.6% |
| Vmpp | 31.9 V | 31.73 V | 0.5% |
| Isc | 14.08 A | 14.01 A | 0.5% |
| Impp | 13.33 A | 13.24 A | 0.7% |
| TcVoc | -0.27 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.56 V | 1.1% |
| Vmpp | 31.9 V | 31.6 V | 0.9% |
| Isc | 14.08 A | 13.98 A | 0.7% |
| Impp | 13.33 A | 13.3 A | 0.2% |
| TcVoc | -0.27 %/°C | -0.27 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.91 V | 0.1% |
| Vmpp | 31.9 V | 31.94 V | 0.1% |
| Isc | 14.08 A | 13.95 A | 0.9% |
| Impp | 13.33 A | 13.15 A | 1.4% |
| TcVoc | -0.27 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.3 %/°C | ±0.040 %/°C |
415 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.86 V | 0.3% |
| Vmpp | 31.9 V | 31.8 V | 0.3% |
| Isc | 14.08 A | 13.79 A | 2.1% |
| Impp | 13.33 A | 13.06 A | 2.0% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
415 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 37.86 V | 0.3% |
| Vmpp | 31.9 V | 31.8 V | 0.3% |
| Isc | 14.08 A | 13.79 A | 2.1% |
| Impp | 13.33 A | 13.06 A | 2.0% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 38.12 V | 0.4% |
| Vmpp | 31.9 V | 32.02 V | 0.4% |
| Isc | 14.08 A | 13.86 A | 1.6% |
| Impp | 13.33 A | 13.13 A | 1.5% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 38.12 V | 0.4% |
| Vmpp | 31.9 V | 32.02 V | 0.4% |
| Isc | 14.08 A | 13.86 A | 1.6% |
| Impp | 13.33 A | 13.13 A | 1.5% |
| TcVoc | -0.27 %/°C | -0.285 %/°C | ±0.015 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 38.11 V | 0.4% |
| Vmpp | 31.9 V | 31.94 V | 0.1% |
| Isc | 14.08 A | 13.95 A | 0.9% |
| Impp | 13.33 A | 13.15 A | 1.4% |
| TcVoc | -0.27 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.3 %/°C | ±0.040 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 38.11 V | 0.4% |
| Vmpp | 31.9 V | 31.94 V | 0.1% |
| Isc | 14.08 A | 13.95 A | 0.9% |
| Impp | 13.33 A | 13.15 A | 1.4% |
| TcVoc | -0.27 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.3 %/°C | ±0.040 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.96 V | 38.11 V | 0.4% |
| Vmpp | 31.9 V | 31.94 V | 0.1% |
| Isc | 14.08 A | 13.95 A | 0.9% |
| Impp | 13.33 A | 13.15 A | 1.4% |
| TcVoc | -0.27 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.3 %/°C | ±0.040 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
37.96 V
Vmpp
31.9 V
Isc
14.08 A
Impp
13.33 A
TcVoc
-0.27 %/°C
TcPmax
-0.34 %/°C
Pmax
425 W
Cells
108
Length
1722 mm
Width
1134 mm
Thickness
30 mm
Weight
22 kg
The Sunway SW425M-108 is a 425 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 405 W | 37.11 V | 13.7 A | |
| 410 W | 37.26 V | 13.79 A | |
| 415 W | 37.41 V | 13.89 A | |
| 420 W | 37.56 V | 13.98 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 37.96 V (within ±5%), and temperature coefficient TcVoc close to -0.27%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sunway SW425M-108.