550 W PERC solar panel with 144 cells. Voc 49.9 V · Isc 13.8 A · TcVoc -0.26%/°C.
Select the panel you want to replace
71 panels found · 3359 panels excluded
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.8 V | 0.2% |
| Vmpp | 42.1 V | 42 V | 0.2% |
| Isc | 13.8 A | 13.71 A | 0.7% |
| Impp | 13.07 A | 12.98 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.8 V | 0.2% |
| Vmpp | 42.1 V | 41.6 V | 1.2% |
| Isc | 13.8 A | 13.99 A | 1.4% |
| Impp | 13.07 A | 13.23 A | 1.2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
540 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.7 V | 0.4% |
| Vmpp | 42.1 V | 41.9 V | 0.5% |
| Isc | 13.8 A | 13.62 A | 1.3% |
| Impp | 13.07 A | 12.89 A | 1.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.95 V | 0.1% |
| Vmpp | 42.1 V | 42.1 V | 0.0% |
| Isc | 13.8 A | 14.04 A | 1.7% |
| Impp | 13.07 A | 13.19 A | 0.9% |
| TcVoc | -0.26 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.82 V | 0.2% |
| Vmpp | 42.1 V | 42 V | 0.2% |
| Isc | 13.8 A | 13.97 A | 1.2% |
| Impp | 13.07 A | 13.1 A | 0.2% |
| TcVoc | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
555 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.97 V | 0.1% |
| Vmpp | 42.1 V | 42.15 V | 0.1% |
| Isc | 13.8 A | 14.04 A | 1.7% |
| Impp | 13.07 A | 13.17 A | 0.8% |
| TcVoc | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.9 V | 0.0% |
| Vmpp | 42.1 V | 41.96 V | 0.3% |
| Isc | 13.8 A | 14 A | 1.4% |
| Impp | 13.07 A | 13.11 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.275 %/°C | ±0.015 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
550 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.8 V | 0.2% |
| Vmpp | 42.1 V | 41.95 V | 0.4% |
| Isc | 13.8 A | 13.98 A | 1.3% |
| Impp | 13.07 A | 13.12 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.265 %/°C | ±0.005 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.9 V | 0.0% |
| Vmpp | 42.1 V | 41.85 V | 0.6% |
| Isc | 13.8 A | 13.61 A | 1.4% |
| Impp | 13.07 A | 12.93 A | 1.1% |
| TcVoc | -0.26 %/°C | -0.268 %/°C | ±0.008 %/°C |
| TcPmax | -0.36 %/°C | -0.34 %/°C | ±0.020 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.76 V | 0.3% |
| Vmpp | 42.1 V | 41.9 V | 0.5% |
| Isc | 13.8 A | 13.9 A | 0.7% |
| Impp | 13.07 A | 13.02 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.27 %/°C | ±0.010 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
535 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.6 V | 0.6% |
| Vmpp | 42.1 V | 41.8 V | 0.7% |
| Isc | 13.8 A | 13.53 A | 2.0% |
| Impp | 13.07 A | 12.8 A | 2.1% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
545 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.9 V | 0.0% |
| Vmpp | 42.1 V | 41.93 V | 0.4% |
| Isc | 13.8 A | 13.81 A | 0.1% |
| Impp | 13.07 A | 13 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.285 %/°C | ±0.025 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.9 V
Vmpp
42.1 V
Isc
13.8 A
Impp
13.07 A
TcVoc
-0.26 %/°C
TcPmax
-0.36 %/°C
Pmax
550 W
Cells
144
Length
2279 mm
Width
1134 mm
Thickness
35 mm
Weight
29 kg
The Sunway SW550M-144 is a 550 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 530 W | 49.5 V | 13.44 A | |
| 535 W | 49.6 V | 13.53 A | |
| 540 W | 49.7 V | 13.62 A | |
| 545 W | 49.8 V | 13.71 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 49.9 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sunway SW550M-144.