Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Support
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for Sunway SW565N-144

565 W TOPCon solar panel with 144 cells. Voc 51.6 V · Isc 13.47 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Panel not in the catalogue?

86 of the 4,444 panels in the catalogue can replace Sunway SW565N-144. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–93 % · 15 models

  • UKSOL UKS-S144-M10N-565-BG — Open the panel page
    565 WTOPCon
    93 %
  • Canadian Solar CS6W-565T — Open the panel page
    565 WTOPCon
    92 %
  • Canadian Solar CS6W-570T — Open the panel page
    570 WTOPCon
    88 %
  • Sunway SW570N-144 — Open the panel page
    570 WTOPConsame series
    87 %
  • Canadian Solar CS6W-560T — Open the panel page
    560 WTOPCon
    86 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 60–77 % · 30 models

  • UKSOL UKS-S144-M10N-575-BG — Open the panel page
    575 WTOPCon
    77 %
  • Amerisolar AS-7M144N-HC-585 — Open the panel page
    585 WTOPCon
    76 %
  • United Energy UE575T-72H — Open the panel page
    575 WTOPCon
    76 %
  • Canadian Solar CS6W-580T — Open the panel page
    580 WTOPCon
    75 %
  • Amerisolar AS-7M144N-HC-580 — Open the panel page
    580 WTOPCon
    74 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 24–58 % · 41 models

  • Amerisolar AS-7M144N-HC-560 — Open the panel page
    560 WTOPCon
    58 %
  • LONGi LR5-72HTH-575M — Open the panel page
    575 WHPBC
    58 %
  • LONGi LR5-72HTHF-575M — Open the panel page
    575 WHPBC
    58 %
  • Maysun Solar MS575BC-72H — Open the panel page
    575 WIBC
    58 %
  • Perlight Solar PLM-570H8N-144 — Open the panel page
    570 WTOPCon
    57 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

51.6 V

Vmpp

42.84 V

Isc

13.47 A

Impp

13.19 A

TcVoc

-0.25 %/°C

TcPmax

-0.29 %/°C

Pmax

565 W

Cells

144

Length

2279 mm

Width

1134 mm

Thickness

30 mm

Weight

32 kg

The Sunway SW565N-144 is a 565 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
SW570N-144570 W52 V13.52 A
SW575N-144575 W52.18 V13.58 A
SW580N-144580 W52.36 V13.61 A
SW585N-144585 W52.48 V13.67 A

Frequently Asked Questions

What specs must match when replacing the Sunway SW565N-144?

The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.6 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Sunway SW565N-144?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sunway SW565N-144.