Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Support
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for TommaTech TT525-108TNB12R

525 W TOPCon solar panel with 108 cells. Voc 40.55 V · Isc 16.13 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Panel not in the catalogue?

54 of the 4,444 panels in the catalogue can replace TommaTech TT525-108TNB12R. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 81–92 % · 12 models

  • Canadian Solar CS6.2-54TM-520 — Open the panel page
    520 WTOPCon
    92 %
  • TommaTech TT520-108TNB12R — Open the panel page
    520 WTOPConsame series
    90 %
  • TommaTech TT530-108TNB12R — Open the panel page
    530 WTOPConsame series
    90 %
  • Canadian Solar CS6.2-54TM-515 — Open the panel page
    515 WTOPCon
    84 %
  • Trina Solar TSM-NEG18R.20-510 — Open the panel page
    510 WTOPCon
    82 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 61–79 % · 29 models

  • Sun Earth DXM10-54H 510W — Open the panel page
    510 WTOPCon
    79 %
  • Ulica Solar UL-515M-108DDGN — Open the panel page
    515 WTOPCon
    79 %
  • Sun Earth DXM10-54H 505W — Open the panel page
    505 WTOPCon
    78 %
  • Trina Solar TSM-NEG18R.20-515 — Open the panel page
    515 WTOPCon
    76 %
  • Trina Solar TSM-NEG18R.25-515 — Open the panel page
    515 WTOPCon
    76 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 36–58 % · 13 models

  • Sun Earth DXM10-54H 525W — Open the panel page
    525 WTOPCon
    58 %
  • Maysun Solar MS520MTDG-54HR — Open the panel page
    520 WTOPCon
    58 %
  • Maysun Solar MS510MTDG-54HR — Open the panel page
    510 WTOPCon
    56 %
  • Aiko Solar AIKO-A505-MCE54Dw — Open the panel page
    505 WABC
    53 %
  • Aiko Solar AIKO-A505-MCE54Mw — Open the panel page
    505 WABC
    53 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

40.55 V

Vmpp

34.35 V

Isc

16.13 A

Impp

15.29 A

TcVoc

-0.25 %/°C

TcPmax

-0.29 %/°C

Pmax

525 W

Cells

108

Length

1965 mm

Width

1134 mm

Thickness

30 mm

Weight

27.8 kg

The TommaTech TT525-108TNB12R is a 525 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
TT510-108TNB12R510 W39.95 V15.95 A
TT515-108TNB12R515 W40.15 V16.01 A
TT520-108TNB12R520 W40.35 V16.07 A
TT530-108TNB12R530 W40.75 V16.19 A
TT535-108TNB12R535 W40.95 V16.25 A

Frequently Asked Questions

What specs must match when replacing the TommaTech TT525-108TNB12R?

The most critical specs to match are: cell count (must be exactly 108), Voc close to 40.55 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the TommaTech TT525-108TNB12R?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original TommaTech TT525-108TNB12R.