720 W TOPCon solar panel with 132 cells. Voc 48.6 V · Isc 18.67 A · TcVoc -0.26%/°C.
Select the panel you want to replace
27 panels found · 3403 panels excluded
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.6 V | 0.0% |
| Vmpp | 40.5 V | 40.5 V | 0.0% |
| Isc | 18.67 A | 18.67 A | 0.0% |
| Impp | 17.78 A | 17.78 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.8 V | 0.4% |
| Vmpp | 40.5 V | 40.7 V | 0.5% |
| Isc | 18.67 A | 18.72 A | 0.3% |
| Impp | 17.78 A | 17.82 A | 0.2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.8 V | 0.4% |
| Vmpp | 40.5 V | 40.7 V | 0.5% |
| Isc | 18.67 A | 18.72 A | 0.3% |
| Impp | 17.78 A | 17.82 A | 0.2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 49 V | 0.8% |
| Vmpp | 40.5 V | 40.9 V | 1.0% |
| Isc | 18.67 A | 18.76 A | 0.5% |
| Impp | 17.78 A | 17.85 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 49 V | 0.8% |
| Vmpp | 40.5 V | 40.9 V | 1.0% |
| Isc | 18.67 A | 18.76 A | 0.5% |
| Impp | 17.78 A | 17.85 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 49 V | 0.8% |
| Vmpp | 40.5 V | 40.9 V | 1.0% |
| Isc | 18.67 A | 18.76 A | 0.5% |
| Impp | 17.78 A | 17.85 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.6 V | 0.0% |
| Vmpp | 40.5 V | 40.5 V | 0.0% |
| Isc | 18.67 A | 18.32 A | 1.9% |
| Impp | 17.78 A | 17.29 A | 2.8% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.32 %/°C | -0.29 %/°C | ±0.030 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.51 V | 0.2% |
| Vmpp | 40.5 V | 40.71 V | 0.5% |
| Isc | 18.67 A | 18.22 A | 2.4% |
| Impp | 17.78 A | 17.2 A | 3.3% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.32 %/°C | -0.29 %/°C | ±0.030 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 49.2 V | 1.2% |
| Vmpp | 40.5 V | 41.1 V | 1.5% |
| Isc | 18.67 A | 18.8 A | 0.7% |
| Impp | 17.78 A | 17.89 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 49.2 V | 1.2% |
| Vmpp | 40.5 V | 41.1 V | 1.5% |
| Isc | 18.67 A | 18.8 A | 0.7% |
| Impp | 17.78 A | 17.89 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 49.2 V | 1.2% |
| Vmpp | 40.5 V | 41.1 V | 1.5% |
| Isc | 18.67 A | 18.8 A | 0.7% |
| Impp | 17.78 A | 17.89 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.32 %/°C | -0.32 %/°C | ±0.000 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.6 V | 48.76 V | 0.3% |
| Vmpp | 40.5 V | 40.85 V | 0.9% |
| Isc | 18.67 A | 18.26 A | 2.2% |
| Impp | 17.78 A | 17.27 A | 2.9% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.32 %/°C | -0.29 %/°C | ±0.030 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.6 V
Vmpp
40.5 V
Isc
18.67 A
Impp
17.78 A
TcVoc
-0.26 %/°C
TcPmax
-0.32 %/°C
Pmax
720 W
Cells
132
Length
2384 mm
Width
1303 mm
Thickness
35 mm
Weight
34.5 kg
The TommaTech TT720-132TNB12 is a 720 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 725 W | 48.8 V | 18.72 A | |
| 730 W | 49 V | 18.76 A | |
| 735 W | 49.2 V | 18.8 A | |
| 740 W | 49.4 V | 18.85 A | |
| 745 W | 49.6 V | 18.89 A | |
| 750 W | 49.8 V | 18.95 A | |
| 755 W | 50 V | 18.99 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.6 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original TommaTech TT720-132TNB12.