415 W PERC solar panel with 144 cells. Voc 50 V · Isc 10.55 A · TcVoc -0.25%/°C.
Select the panel you want to replace
10 panels found · 3690 panels excluded
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 50.1 V | 0.2% |
| Vmpp | 41.7 V | 42 V | 0.7% |
| Isc | 10.55 A | 10.58 A | 0.3% |
| Impp | 9.94 A | 10.01 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
425 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 50.2 V | 0.4% |
| Vmpp | 41.7 V | 42.2 V | 1.2% |
| Isc | 10.55 A | 10.61 A | 0.6% |
| Impp | 9.94 A | 10.08 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
430 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 50.3 V | 0.6% |
| Vmpp | 41.7 V | 42.3 V | 1.4% |
| Isc | 10.55 A | 10.64 A | 0.9% |
| Impp | 9.94 A | 10.17 A | 2.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 50.4 V | 0.8% |
| Vmpp | 41.7 V | 42.5 V | 1.9% |
| Isc | 10.55 A | 10.67 A | 1.1% |
| Impp | 9.94 A | 10.24 A | 3.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 49.59 V | 0.8% |
| Vmpp | 41.7 V | 41.21 V | 1.2% |
| Isc | 10.55 A | 11.25 A | 6.6% |
| Impp | 9.94 A | 10.56 A | 6.2% |
| TcVoc | -0.25 %/°C | -0.285 %/°C | ±0.035 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 50.9 V | 1.8% |
| Vmpp | 41.7 V | 42.9 V | 2.9% |
| Isc | 10.55 A | 10.56 A | 0.1% |
| Impp | 9.94 A | 9.92 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.29 %/°C | ±0.050 %/°C |
430 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 49.39 V | 1.2% |
| Vmpp | 41.7 V | 41.01 V | 1.7% |
| Isc | 10.55 A | 11.19 A | 6.1% |
| Impp | 9.94 A | 10.49 A | 5.5% |
| TcVoc | -0.25 %/°C | -0.285 %/°C | ±0.035 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 51.4 V | 2.8% |
| Vmpp | 41.7 V | 43.2 V | 3.6% |
| Isc | 10.55 A | 10.59 A | 0.4% |
| Impp | 9.94 A | 9.96 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.29 %/°C | ±0.050 %/°C |
425 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 49.19 V | 1.6% |
| Vmpp | 41.7 V | 40.81 V | 2.1% |
| Isc | 10.55 A | 11.11 A | 5.3% |
| Impp | 9.94 A | 10.42 A | 4.8% |
| TcVoc | -0.25 %/°C | -0.285 %/°C | ±0.035 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
420 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50 V | 49.01 V | 2.0% |
| Vmpp | 41.7 V | 40.61 V | 2.6% |
| Isc | 10.55 A | 11.04 A | 4.6% |
| Impp | 9.94 A | 10.35 A | 4.1% |
| TcVoc | -0.25 %/°C | -0.285 %/°C | ±0.035 %/°C |
| TcPmax | -0.34 %/°C | -0.35 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50 V
Vmpp
41.7 V
Isc
10.55 A
Impp
9.94 A
TcVoc
-0.25 %/°C
TcPmax
-0.34 %/°C
Pmax
415 W
Cells
144
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
21.8 kg
The Trina Solar TSM-DE09R.08-415 is a 415 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 420 W | 50.1 V | 10.58 A | |
| 425 W | 50.2 V | 10.61 A | |
| 430 W | 50.3 V | 10.64 A | |
| 435 W | 50.4 V | 10.67 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 50 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Trina Solar TSM-DE09R.08-415.