560 W IBC solar panel with 144 cells. Voc 51.61 V · Isc 13.97 A · TcVoc -0.23%/°C.
Select the panel you want to replace
47 panels found · 3653 panels excluded
565 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.76 V | 0.3% |
| Vmpp | 43.56 V | 43.61 V | 0.1% |
| Isc | 13.97 A | 14.01 A | 0.3% |
| Impp | 12.92 A | 12.96 A | 0.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.76 V | 0.3% |
| Vmpp | 43.56 V | 43.61 V | 0.1% |
| Isc | 13.97 A | 14.01 A | 0.3% |
| Impp | 12.92 A | 12.96 A | 0.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.86 V | 0.5% |
| Vmpp | 43.56 V | 43.61 V | 0.1% |
| Isc | 13.97 A | 14.03 A | 0.4% |
| Impp | 12.92 A | 12.98 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.91 V | 0.6% |
| Vmpp | 43.56 V | 43.76 V | 0.5% |
| Isc | 13.97 A | 14.07 A | 0.7% |
| Impp | 12.92 A | 13.03 A | 0.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.91 V | 0.6% |
| Vmpp | 43.56 V | 43.76 V | 0.5% |
| Isc | 13.97 A | 14.07 A | 0.7% |
| Impp | 12.92 A | 13.03 A | 0.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.91 V | 0.6% |
| Vmpp | 43.56 V | 43.86 V | 0.7% |
| Isc | 13.97 A | 14.09 A | 0.9% |
| Impp | 12.92 A | 13.05 A | 1.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 51.59 V | 0.0% |
| Vmpp | 43.56 V | 43.32 V | 0.6% |
| Isc | 13.97 A | 14.02 A | 0.4% |
| Impp | 12.92 A | 13.39 A | 3.6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 52.06 V | 0.9% |
| Vmpp | 43.56 V | 43.91 V | 0.8% |
| Isc | 13.97 A | 14.14 A | 1.2% |
| Impp | 12.92 A | 13.1 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 52.06 V | 0.9% |
| Vmpp | 43.56 V | 43.91 V | 0.8% |
| Isc | 13.97 A | 14.14 A | 1.2% |
| Impp | 12.92 A | 13.1 A | 1.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 52.06 V | 0.9% |
| Vmpp | 43.56 V | 43.91 V | 0.8% |
| Isc | 13.97 A | 14.15 A | 1.3% |
| Impp | 12.92 A | 13.11 A | 1.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 52.21 V | 1.2% |
| Vmpp | 43.56 V | 44.06 V | 1.1% |
| Isc | 13.97 A | 14.2 A | 1.6% |
| Impp | 12.92 A | 13.17 A | 1.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.61 V | 52.21 V | 1.2% |
| Vmpp | 43.56 V | 44.06 V | 1.1% |
| Isc | 13.97 A | 14.21 A | 1.7% |
| Impp | 12.92 A | 13.18 A | 2.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.61 V
Vmpp
43.56 V
Isc
13.97 A
Impp
12.92 A
TcVoc
-0.23 %/°C
TcPmax
-0.29 %/°C
Pmax
560 W
Cells
144
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
27.2 kg
The Maysun Solar MS560BC-72H is a 560 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 565 W | 51.86 V | 14.03 A | |
| 570 W | 51.91 V | 14.09 A | |
| 575 W | 52.06 V | 14.15 A | |
| 580 W | 52.21 V | 14.21 A | |
| 585 W | 52.36 V | 14.27 A | |
| 590 W | 52.51 V | 14.33 A | |
| 595 W | 52.66 V | 14.4 A | |
| 600 W | 52.81 V | 14.46 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.61 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Maysun Solar MS560BC-72H.