Find replacement for Maysun Solar MS590BC-72H

590 W IBC solar panel with 144 cells. Voc 52.51 V · Isc 14.33 A · TcVoc -0.23%/°C.

Select the panel you want to replace

Panel not in the catalogue?

131 of the 4,444 panels in the catalogue can replace Maysun Solar MS590BC-72H. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Exact match

Near-identical electrics — a drop-in swap for the same string.

Match 100 % · 2 models

  • LONGi LR5-72HTH-590M — Open the panel page
    590 WHPBC
    100 %
  • LONGi LR5-72HTHF-590M — Open the panel page
    590 WHPBC
    100 %

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–94 % · 25 models

  • Maysun Solar MS585BC-72H — Open the panel page
    585 WIBCsame series
    94 %
  • Maysun Solar MS595BC-72H — Open the panel page
    595 WIBCsame series
    94 %
  • LONGi LR5-72HTH-585M — Open the panel page
    585 WHPBC
    94 %
  • LONGi LR5-72HTH-595M — Open the panel page
    595 WHPBC
    94 %
  • LONGi LR5-72HTHF-585M — Open the panel page
    585 WHPBC
    94 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 61–79 % · 62 models

  • UKSOL UKS-S144-M10N-585-BG — Open the panel page
    585 WTOPCon
    79 %
  • UKSOL UKS-S144-M10N-595-BG — Open the panel page
    595 WTOPCon
    79 %
  • Horay Solar HS605TC-MHB — Open the panel page
    605 WTOPCon
    78 %
  • Sun Earth DXM8-72H 610W — Open the panel page
    610 WTOPCon
    77 %
  • United Energy UE580T-72H 590W — Open the panel page
    590 WTOPCon
    77 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 26–59 % · 42 models

  • Canadian Solar CS6.1-72TD-595 — Open the panel page
    595 WTOPCon
    59 %
  • Sun Earth DXM8-72H 590W — Open the panel page
    590 WTOPCon
    59 %
  • Ulica Solar UL-585M-144AHVN — Open the panel page
    585 WTOPCon
    59 %
  • TommaTech TT590-144TN10 — Open the panel page
    590 WTOPCon
    58 %
  • TommaTech TT590-144TNB10 — Open the panel page
    590 WTOPCon
    58 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

52.51 V

Vmpp

44.36 V

Isc

14.33 A

Impp

13.31 A

TcVoc

-0.23 %/°C

TcPmax

-0.29 %/°C

Pmax

590 W

Cells

144

Length

2278 mm

Width

1134 mm

Thickness

30 mm

Weight

27.2 kg

The Maysun Solar MS590BC-72H is a 590 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
MS560BC-72H560 W51.61 V13.97 A
MS565BC-72H565 W51.86 V14.03 A
MS570BC-72H570 W51.91 V14.09 A
MS575BC-72H575 W52.06 V14.15 A
MS580BC-72H580 W52.21 V14.21 A
MS585BC-72H585 W52.36 V14.27 A
MS595BC-72H595 W52.66 V14.4 A
MS600BC-72H600 W52.81 V14.46 A

Frequently Asked Questions

What specs must match when replacing the Maysun Solar MS590BC-72H?

The most critical specs to match are: cell count (must be exactly 144), Voc close to 52.51 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Maysun Solar MS590BC-72H?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Maysun Solar MS590BC-72H.