605 W TOPCon solar panel with 132 cells. Voc 48.49 V · Isc 15.86 A · TcVoc -0.22%/°C.
Select the panel you want to replace
24 panels found · 3686 panels excluded
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.29 V | 0.4% |
| Vmpp | 40.28 V | 40.11 V | 0.4% |
| Isc | 15.86 A | 15.8 A | 0.4% |
| Impp | 15.02 A | 14.96 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.69 V | 0.4% |
| Vmpp | 40.28 V | 40.46 V | 0.4% |
| Isc | 15.86 A | 15.92 A | 0.4% |
| Impp | 15.02 A | 15.08 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.89 V | 0.8% |
| Vmpp | 40.28 V | 40.64 V | 0.9% |
| Isc | 15.86 A | 15.98 A | 0.8% |
| Impp | 15.02 A | 15.14 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 49.08 V | 1.2% |
| Vmpp | 40.28 V | 40.81 V | 1.3% |
| Isc | 15.86 A | 16.04 A | 1.1% |
| Impp | 15.02 A | 15.2 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.4 V | 0.2% |
| Vmpp | 40.28 V | 40.3 V | 0.0% |
| Isc | 15.86 A | 15.8 A | 0.4% |
| Impp | 15.02 A | 14.91 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.4 V | 0.2% |
| Vmpp | 40.28 V | 40.3 V | 0.0% |
| Isc | 15.86 A | 15.8 A | 0.4% |
| Impp | 15.02 A | 14.91 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.7 V | 0.4% |
| Vmpp | 40.28 V | 40.5 V | 0.5% |
| Isc | 15.86 A | 15.83 A | 0.2% |
| Impp | 15.02 A | 14.94 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.7 V | 0.4% |
| Vmpp | 40.28 V | 40.5 V | 0.5% |
| Isc | 15.86 A | 15.83 A | 0.2% |
| Impp | 15.02 A | 14.94 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 49 V | 1.1% |
| Vmpp | 40.28 V | 40.8 V | 1.3% |
| Isc | 15.86 A | 15.86 A | 0.0% |
| Impp | 15.02 A | 14.96 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 49 V | 1.1% |
| Vmpp | 40.28 V | 40.8 V | 1.3% |
| Isc | 15.86 A | 15.86 A | 0.0% |
| Impp | 15.02 A | 14.96 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.99 V | 1.0% |
| Vmpp | 40.28 V | 41.02 V | 1.8% |
| Isc | 15.86 A | 16.02 A | 1.0% |
| Impp | 15.02 A | 15.12 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.26 %/°C | ±0.040 %/°C |
| TcPmax | -0.24 %/°C | -0.3 %/°C | ±0.060 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.49 V | 48.99 V | 1.0% |
| Vmpp | 40.28 V | 41.02 V | 1.8% |
| Isc | 15.86 A | 16.02 A | 1.0% |
| Impp | 15.02 A | 15.12 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.26 %/°C | ±0.040 %/°C |
| TcPmax | -0.24 %/°C | -0.3 %/°C | ±0.060 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.49 V
Vmpp
40.28 V
Isc
15.86 A
Impp
15.02 A
TcVoc
-0.22 %/°C
TcPmax
-0.24 %/°C
Pmax
605 W
Cells
132
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
35.6 kg
The Maysun Solar MS605MTDG-66HR is a 605 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| MS600MTDG-66HR | 600 W | 48.29 V | 15.8 A |
| MS610MTDG-66HR | 610 W | 48.69 V | 15.92 A |
| MS615MTDG-66HR | 615 W | 48.89 V | 15.98 A |
| MS620MTDG-66HR | 620 W | 49.08 V | 16.04 A |
| MS630MTDG-66HR | 630 W | 49.27 V | 16.11 A |
| MS640MTDG-66HR | 640 W | 49.46 V | 16.19 A |
| MS650MTDG-66HR | 650 W | 49.65 V | 16.27 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.49 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Maysun Solar MS605MTDG-66HR.