615 W TOPCon solar panel with 132 cells. Voc 48.89 V · Isc 15.98 A · TcVoc -0.22%/°C.
Select the panel you want to replace
Panel not in the catalogue?
48 of the 4,444 panels in the catalogue can replace Maysun Solar MS615MTDG-66HR. Before you buy, check your pick in the string calculator with your inverter.
CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.
Small differences within tolerance — safe once verified in the calculator with your inverter.
Match 84–92 % · 4 models
Noticeable differences — the string voltage and current need a careful check.
Match 61–76 % · 15 models
Large differences — a real risk of a mismatched string; prefer a closer panel.
Match 35–59 % · 29 models
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.89 V
Vmpp
40.64 V
Isc
15.98 A
Impp
15.14 A
TcVoc
-0.22 %/°C
TcPmax
-0.24 %/°C
Pmax
615 W
Cells
132
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
35.6 kg
The Maysun Solar MS615MTDG-66HR is a 615 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| MS600MTDG-66HR | 600 W | 48.29 V | 15.8 A |
| MS605MTDG-66HR | 605 W | 48.49 V | 15.86 A |
| MS610MTDG-66HR | 610 W | 48.69 V | 15.92 A |
| MS620MTDG-66HR | 620 W | 49.08 V | 16.04 A |
| MS630MTDG-66HR | 630 W | 49.27 V | 16.11 A |
| MS640MTDG-66HR | 640 W | 49.46 V | 16.19 A |
| MS650MTDG-66HR | 650 W | 49.65 V | 16.27 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.89 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Maysun Solar MS615MTDG-66HR.