610 W TOPCon solar panel with 156 cells. Voc 55.1 V · Isc 14.11 A · TcVoc -0.25%/°C.
Select the panel you want to replace
38 panels found · 3662 panels excluded
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.3 V | 0.4% |
| Vmpp | 45.7 V | 45.9 V | 0.4% |
| Isc | 14.11 A | 14.16 A | 0.4% |
| Impp | 13.35 A | 13.4 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.5 V | 0.7% |
| Vmpp | 45.7 V | 46.1 V | 0.9% |
| Isc | 14.11 A | 14.21 A | 0.7% |
| Impp | 13.35 A | 13.45 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.7 V | 1.1% |
| Vmpp | 45.7 V | 46.3 V | 1.3% |
| Isc | 14.11 A | 14.26 A | 1.1% |
| Impp | 13.35 A | 13.5 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.74 V | 1.2% |
| Vmpp | 45.7 V | 46.09 V | 0.9% |
| Isc | 14.11 A | 14.27 A | 1.1% |
| Impp | 13.35 A | 13.56 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.6 V | 0.9% |
| Vmpp | 45.7 V | 46.8 V | 2.4% |
| Isc | 14.11 A | 14.08 A | 0.2% |
| Impp | 13.35 A | 13.25 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.84 V | 1.3% |
| Vmpp | 45.7 V | 45.96 V | 0.6% |
| Isc | 14.11 A | 14.38 A | 1.9% |
| Impp | 13.35 A | 13.71 A | 2.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.6 V | 0.9% |
| Vmpp | 45.7 V | 46.8 V | 2.4% |
| Isc | 14.11 A | 14.08 A | 0.2% |
| Impp | 13.35 A | 13.25 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.6 V | 0.9% |
| Vmpp | 45.7 V | 46.8 V | 2.4% |
| Isc | 14.11 A | 14.08 A | 0.2% |
| Impp | 13.35 A | 13.25 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.88 V | 1.4% |
| Vmpp | 45.7 V | 46.26 V | 1.2% |
| Isc | 14.11 A | 14.35 A | 1.7% |
| Impp | 13.35 A | 13.62 A | 2.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.88 V | 1.4% |
| Vmpp | 45.7 V | 45.96 V | 0.6% |
| Isc | 14.11 A | 14.4 A | 2.1% |
| Impp | 13.35 A | 13.71 A | 2.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.83 V | 1.3% |
| Vmpp | 45.7 V | 46.67 V | 2.1% |
| Isc | 14.11 A | 14.16 A | 0.4% |
| Impp | 13.35 A | 13.3 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 55.1 V | 55.9 V | 1.5% |
| Vmpp | 45.7 V | 46.5 V | 1.8% |
| Isc | 14.11 A | 14.31 A | 1.4% |
| Impp | 13.35 A | 13.55 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
55.1 V
Vmpp
45.7 V
Isc
14.11 A
Impp
13.35 A
TcVoc
-0.25 %/°C
TcPmax
-0.3 %/°C
Pmax
610 W
Cells
156
Bifaciality
80%
Length
2465 mm
Width
1134 mm
Thickness
30 mm
Weight
34.5 kg
The RECOM RCM-610-7DBNN is a 610 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 615 W | 55.3 V | 14.16 A | |
| 620 W | 55.5 V | 14.21 A | |
| 625 W | 55.7 V | 14.26 A | |
| 630 W | 55.9 V | 14.31 A | |
| 635 W | 56.1 V | 14.36 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 55.1 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original RECOM RCM-610-7DBNN.