635 W TOPCon solar panel with 156 cells. Voc 56.1 V · Isc 14.36 A · TcVoc -0.25%/°C.
Select the panel you want to replace
74 panels found · 3626 panels excluded
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.18 V | 0.1% |
| Vmpp | 46.7 V | 46.59 V | 0.2% |
| Isc | 14.36 A | 14.48 A | 0.8% |
| Impp | 13.6 A | 13.74 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.01 V | 0.2% |
| Vmpp | 46.7 V | 46.42 V | 0.6% |
| Isc | 14.36 A | 14.42 A | 0.4% |
| Impp | 13.6 A | 13.68 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 55.9 V | 0.4% |
| Vmpp | 46.7 V | 46.5 V | 0.4% |
| Isc | 14.36 A | 14.31 A | 0.3% |
| Impp | 13.6 A | 13.55 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.01 V | 0.2% |
| Vmpp | 46.7 V | 46.82 V | 0.3% |
| Isc | 14.36 A | 14.22 A | 1.0% |
| Impp | 13.6 A | 13.36 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 55.88 V | 0.4% |
| Vmpp | 46.7 V | 46.26 V | 0.9% |
| Isc | 14.36 A | 14.35 A | 0.1% |
| Impp | 13.6 A | 13.62 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.2 V | 0.2% |
| Vmpp | 46.7 V | 46.98 V | 0.6% |
| Isc | 14.36 A | 14.28 A | 0.6% |
| Impp | 13.6 A | 13.42 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.14 V | 0.1% |
| Vmpp | 46.7 V | 46.16 V | 1.2% |
| Isc | 14.36 A | 14.52 A | 1.1% |
| Impp | 13.6 A | 13.87 A | 2.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.36 V | 0.5% |
| Vmpp | 46.7 V | 46.78 V | 0.2% |
| Isc | 14.36 A | 14.53 A | 1.2% |
| Impp | 13.6 A | 13.79 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 55.99 V | 0.2% |
| Vmpp | 46.7 V | 46.06 V | 1.4% |
| Isc | 14.36 A | 14.45 A | 0.6% |
| Impp | 13.6 A | 13.79 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.03 V | 0.1% |
| Vmpp | 46.7 V | 46.06 V | 1.4% |
| Isc | 14.36 A | 14.47 A | 0.8% |
| Impp | 13.6 A | 13.79 A | 1.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56 V | 0.2% |
| Vmpp | 46.7 V | 47.2 V | 1.1% |
| Isc | 14.36 A | 14.2 A | 1.1% |
| Impp | 13.6 A | 13.35 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.1 V | 56.18 V | 0.1% |
| Vmpp | 46.7 V | 46.16 V | 1.2% |
| Isc | 14.36 A | 14.54 A | 1.3% |
| Impp | 13.6 A | 13.86 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
56.1 V
Vmpp
46.7 V
Isc
14.36 A
Impp
13.6 A
TcVoc
-0.25 %/°C
TcPmax
-0.3 %/°C
Pmax
635 W
Cells
156
Bifaciality
80%
Length
2465 mm
Width
1134 mm
Thickness
30 mm
Weight
34.5 kg
The RECOM RCM-635-7DBNN is a 635 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 610 W | 55.1 V | 14.11 A | |
| 615 W | 55.3 V | 14.16 A | |
| 620 W | 55.5 V | 14.21 A | |
| 625 W | 55.7 V | 14.26 A | |
| 630 W | 55.9 V | 14.31 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 56.1 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original RECOM RCM-635-7DBNN.