715 W HJT solar panel with 132 cells. Voc 50.22 V · Isc 17.98 A · TcVoc -0.24%/°C.
Select the panel you want to replace
Panel not in the catalogue?
244 of the 4,444 panels in the catalogue can replace Bluesun Solar BSM715G12-66HNH. Before you buy, check your pick in the string calculator with your inverter.
Close or harmlessNoticeableLarge differenceTap or click a difference to see what it means for your string.
Near-identical electrics — a drop-in swap for the same string.
Match 95–97 % · 30 models
Small differences within tolerance — safe once verified in the calculator with your inverter.
Match 81–94 % · 91 models
Noticeable differences — the string voltage and current need a careful check.
Match 66–79 % · 117 models
Large differences — a real risk of a mismatched string; prefer a closer panel.
Match 55 % · 6 models
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50.22 V
Vmpp
41.84 V
Isc
17.98 A
Impp
17.09 A
TcVoc
-0.24 %/°C
TcPmax
-0.24 %/°C
Pmax
715 W
Cells
132
Bifaciality
80%
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
36.6 kg
The Bluesun Solar BSM715G12-66HNH is a 715 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| BSM720G12-66HNH | 720 W | 50.3 V | 18.08 A |
| BSM725G12-66HNH | 725 W | 50.38 V | 18.18 A |
| BSM730G12-66HNH | 730 W | 50.46 V | 18.28 A |
| BSM735G12-66HNH | 735 W | 50.54 V | 18.37 A |
Match the voltage, not the cell count or the wattage. The replacement's open-circuit voltage should be no more than 2 % above 50.22 V and its working voltage within 5 % of the original; its working current should not be more than 3 % lower, because the weakest panel in a string sets the current for all of them. A temperature coefficient closer to zero than -0.24 %/°C is fine — it adds less voltage in frost. The finder above screens the whole catalogue by these rules.
Yes, if its voltage matches. A higher-wattage panel of the same voltage simply has more current, and a string only carries as much as its weakest panel gives, so the extra goes unused at no risk to the string. Two things to check: its higher short-circuit current against the inverter's rating, and its frame, which is usually larger. The finder shows both; verify the pick in the String Compatibility Calculator with your inverter before installing.
If its Voc is higher, the string comes closer to the inverter's maximum voltage on frosty mornings, when voltage climbs by the TcVoc coefficient; if its Vmpp is lower, the string can drop out of the inverter's working range (MPPT) on hot days. The finder scores each difference only in the direction that hurts — a lower Voc or a flatter coefficient costs nothing — and ranks candidates by how closely they match the Bluesun Solar BSM715G12-66HNH.