730 W HJT solar panel with 132 cells. Voc 50.46 V · Isc 18.28 A · TcVoc -0.24%/°C.
Select the panel you want to replace
110 panels found · 3590 panels excluded
725 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.38 V | 0.2% |
| Vmpp | 42.13 V | 42.03 V | 0.2% |
| Isc | 18.28 A | 18.18 A | 0.5% |
| Impp | 17.33 A | 17.25 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
735 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.54 V | 0.2% |
| Vmpp | 42.13 V | 42.22 V | 0.2% |
| Isc | 18.28 A | 18.37 A | 0.5% |
| Impp | 17.33 A | 17.41 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.4 V | 0.1% |
| Vmpp | 42.13 V | 42.48 V | 0.8% |
| Isc | 18.28 A | 18.18 A | 0.5% |
| Impp | 17.33 A | 16.95 A | 2.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
720 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.3 V | 0.3% |
| Vmpp | 42.13 V | 41.94 V | 0.5% |
| Isc | 18.28 A | 18.08 A | 1.1% |
| Impp | 17.33 A | 17.17 A | 0.9% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
715 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.35 V | 0.2% |
| Vmpp | 42.13 V | 42.44 V | 0.7% |
| Isc | 18.28 A | 18.1 A | 1.0% |
| Impp | 17.33 A | 16.85 A | 2.8% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
715 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.22 V | 0.5% |
| Vmpp | 42.13 V | 41.84 V | 0.7% |
| Isc | 18.28 A | 17.98 A | 1.6% |
| Impp | 17.33 A | 17.09 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.42 V | 0.1% |
| Vmpp | 42.13 V | 42.35 V | 0.5% |
| Isc | 18.28 A | 18.33 A | 0.3% |
| Impp | 17.33 A | 17.24 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.33 V | 0.3% |
| Vmpp | 42.13 V | 42.2 V | 0.2% |
| Isc | 18.28 A | 18.38 A | 0.5% |
| Impp | 17.33 A | 17.32 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
730 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.37 V | 0.2% |
| Vmpp | 42.13 V | 42.32 V | 0.5% |
| Isc | 18.28 A | 18.35 A | 0.4% |
| Impp | 17.33 A | 17.26 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
735 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.4 V | 0.1% |
| Vmpp | 42.13 V | 42.26 V | 0.3% |
| Isc | 18.28 A | 18.47 A | 1.0% |
| Impp | 17.33 A | 17.41 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
735 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.47 V | 0.0% |
| Vmpp | 42.13 V | 42.41 V | 0.7% |
| Isc | 18.28 A | 18.44 A | 0.9% |
| Impp | 17.33 A | 17.34 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
740 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.46 V | 50.47 V | 0.0% |
| Vmpp | 42.13 V | 42.32 V | 0.5% |
| Isc | 18.28 A | 18.56 A | 1.5% |
| Impp | 17.33 A | 17.5 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50.46 V
Vmpp
42.13 V
Isc
18.28 A
Impp
17.33 A
TcVoc
-0.24 %/°C
TcPmax
-0.24 %/°C
Pmax
730 W
Cells
132
Bifaciality
80%
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
36.6 kg
The Bluesun Solar BSM730G12-66HNH is a 730 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 715 W | 50.22 V | 17.98 A | |
| 720 W | 50.3 V | 18.08 A | |
| 725 W | 50.38 V | 18.18 A | |
| 735 W | 50.54 V | 18.37 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 50.46 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Bluesun Solar BSM730G12-66HNH.