Find replacement for Bluesun Solar BSM725G12-66HNH

725 W HJT solar panel with 132 cells. Voc 50.38 V · Isc 18.18 A · TcVoc -0.24%/°C.

Select the panel you want to replace

Panel not in the catalogue?

138 of the 4,444 panels in the catalogue can replace Bluesun Solar BSM725G12-66HNH. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Exact match

Near-identical electrics — a drop-in swap for the same string.

Match 96 % · 2 models

  • Bluesun Solar BSM720G12-66HNH — Open the panel page
    720 WHJTsame series
    96 %
  • Bluesun Solar BSM730G12-66HNH — Open the panel page
    730 WHJTsame series
    96 %

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–93 % · 25 models

  • Jetion Solar JT720SLk(B) — Open the panel page
    720 WHJT
    93 %
  • Jetion Solar JT715SLk(B) — Open the panel page
    715 WHJT
    92 %
  • Bluesun Solar BSM715G12-66HNH — Open the panel page
    715 WHJTsame series
    91 %
  • Bluesun Solar BSM735G12-66HNH — Open the panel page
    735 WHJTsame series
    91 %
  • Jetion Solar JT710SLk(B) — Open the panel page
    710 WHJT
    86 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 61–79 % · 27 models

  • Waaree Energies BiH-11-710 — Open the panel page
    710 WHJT
    79 %
  • Trina Solar TSM-NEG21C.20-740 — Open the panel page
    740 WTOPCon
    79 %
  • Waaree Energies BiH-11-730 — Open the panel page
    730 WHJT
    78 %
  • Seraphim SRP-715-BHC-BG — Open the panel page
    715 WHJT
    78 %
  • Huasun HSN-210-B132DS715 — Open the panel page
    715 WHJT
    77 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 34–59 % · 84 models

  • Trina Solar TSM-NEG21C.20-725 — Open the panel page
    725 WTOPCon
    59 %
  • Tongwei TWMNF-66HD735 — Open the panel page
    735 WTOPCon
    59 %
  • AE Solar CME-132BDS-730 — Open the panel page
    730 WTOPCon
    58 %
  • Horay Solar HS725TC-MHG-D — Open the panel page
    725 WTOPCon
    56 %
  • Luxor Solar LX-705M/210-132+ GG HJT SW ECOLINE — Open the panel page
    705 WHJT
    56 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

50.38 V

Vmpp

42.03 V

Isc

18.18 A

Impp

17.25 A

TcVoc

-0.24 %/°C

TcPmax

-0.24 %/°C

Pmax

725 W

Cells

132

Bifaciality

80%

Length

2384 mm

Width

1303 mm

Thickness

33 mm

Weight

36.6 kg

The Bluesun Solar BSM725G12-66HNH is a 725 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
BSM715G12-66HNH715 W50.22 V17.98 A
BSM720G12-66HNH720 W50.3 V18.08 A
BSM730G12-66HNH730 W50.46 V18.28 A
BSM735G12-66HNH735 W50.54 V18.37 A

Frequently Asked Questions

What specs must match when replacing the Bluesun Solar BSM725G12-66HNH?

The most critical specs to match are: cell count (must be exactly 132), Voc close to 50.38 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Bluesun Solar BSM725G12-66HNH?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Bluesun Solar BSM725G12-66HNH.